Marco Island Reverse Osmosis Water Treatment Plant

  Owner: Florida Water Services, Inc.
  Engineer: Boyle Engineering Corporation
"The 1 million gallon per day Application: Potable Drinking Water
expansion to the existing Start Up Date: June 1996
Marco Island, Florida brackish Capacity: 1.0 MGD
R/O plant was the first Array: One Train, 22:16 6 element vessels
application in the country to Membrane: Fluid Systems TFC® 8822XR and 8822HR
incorporate an energy-recovery, Operating Data: Feedwater TDS: 8500 mg/l
interstage booster."   Permeate TDS: 186 mg/l
    1st Pass Feed Pressure: 340 PSI
    2nd Pass Feed Pressure: 400 PSI
    Recovery: 75%
  System Features: Interstage booster allows both passes to
balance hydraulically
    Control system enables plant to automatically
adjust to varying salinity
    Seawater elements utilized in 1st pass to
control permeate flux and produce highest
quality permeate
     